ADSS Single Jacket All-Dielectric Self-Supporting Fiber optic cable is idea for installation in distribution as well as transmission envirline installations are required as its name indicates, there is no support or messenger wire required, so installation is achieved in a single pass.Structural features:Single layer ,Loose tube stranding, Non-metal strength member, Half dry water-blocking, Aramid yarn strength member, PE outer jacket. Includes 2 core, 4 core, 6 core, 8 core, 12 core, 16 core, 24 core, 36 core, 48 core, 96 core, up to 144 core.
2-144 Core Single Jackets ADSS Cable Specifications:
Cable fiber count
|
/
|
2~30
|
32~60
|
62~72
|
96
|
144
|
Structure
|
/
|
1+5
|
1+5
|
1+6
|
1+8
|
1+12
|
Fiber style
|
/
|
G.652D
|
Central strength member
|
material
|
mm
|
FRP
|
Diameter (average)
|
1.5
|
1.5
|
2.1
|
2.1
|
2.1
|
Loose Tube
|
Material
|
mm
|
PBT
|
Diameter (average)
|
1.8
|
2.1
|
2.1
|
2.1
|
2.1
|
Thickness(average)
|
0.32
|
0.35
|
0.35
|
0.35
|
0.35
|
Max fiber/loose tube
|
6
|
12
|
12
|
12
|
12
|
Tubes color
|
Full color identification
|
Fiber excess length
|
%
|
0.7~0.8
|
Water resistance
|
Material
|
/
|
Cable jelly + water resistant layer
|
Non-metallic strengthen components
|
Material
|
/
|
Aramid Yarn
|
Outer sheath
|
material
|
mm
|
MDPE
|
Outer sheath
|
1.8mm
|
Cable diameter(average)
|
mm
|
9.6
|
10.2
|
10.8
|
12.1
|
15
|
Cable weight (Approximate)
|
kg/km
|
70
|
80
|
90
|
105
|
125
|
Cable Sectional area
|
mm2
|
72.38
|
81.72
|
91.61
|
115
|
176.7
|
Attenuation coefficient(Max)
|
1310nm
|
dB/km
|
0.35
|
1550nm
|
0.21
|
Rated Tensile Strength(RTS)
|
kn
|
5.8
|
Max allowed tension( MAT)
|
kn
|
2.2
|
Annual average operating tension (EDS)
|
kn
|
3.0
|
Young’s modulus
|
kn/mm2
|
7.6
|
Coefficient of thermal expansion
|
10-6/℃
|
9.3
|
Crush resistance
|
Long term
|
N/100mm
|
1100
|
Short term
|
2200
|
Permission Bent Radius
|
static
|
mm
|
15 of OD
|
dynamic
|
20 of OD
|
Temperature
|
When laying
|
℃
|
-20~+60
|
Storage and transportation
|
-40~+70
|
runing
|
-40~+70
|
Scope of application
|
Suitable for voltage level under 110kV, wind speed below 25m/s, icing 5mm
|
Cable Marks
|
Company Name ADSS-××B1-PE-100M DL/T 788-2001 ××××M Year
(Or at customer’s request)
|
What will affect the price of ADSS?
All Dielectric Self Supporting ADSS Cable is laid next to the power cable, so the material of the outer sheath needs to be designed according to the voltage. If it exceeds 110KV, it needs to use AT material, and if it is less than 110KV, it will use PE material.
The wind speed at the laying site, the thickness of the ice, the average temperature, and the most important span (the span refers to the distance between two utility poles) will all affect the tensile strength of the ADSS. If the tensile strength is not enough, the optical cable will be easily to be pulled off.
Finally, the customer should inform the number of fibers of the required ADSS cable, so that the engineer can design the ADSS according to the requirements.
Fiber Type |
□ Single Mode B1-G.652D-9/125mm
□ Single Mode B4-G.655
□ Multi Model A1a-50/125mm
□ Multi Model A1b-62.5/125mm
□ Or Customer Specified
|
|
Fiber Cores |
□ 2Cores
□ 4Cores
□ 6Cores
□ 8Cores
□ 12Cores
□ 24Cores
□ 36Cores
□ 48Cores
□ 72Cores
□ 96Cores
□ 144Cores
□ Or Customer Specified
|
|
Installation Span |
□ 50Meter
□ 80Meter
□ 100Meter
□ 120Meter
□ 150Meter
□ 200Meter
□ 250Meter
□ 300Meter
□ 400Meter
□ 600Meter
□ Or Customer Specified
|
|
Max. Allowable Tension |
□ 4KN
□ 6KN
□ 9KN
□ 12KN
□ 15KN
□ 18KN
□ 19KN
□ 21KN
□ 24KN
□ 26KN
□ 27KN
□ Or Customer Specified
|
|
Sheath / Jacket (Materials) |
□ PE
□ AT
|
Voltage grade: <110KV
Voltage grade: >110KV |
Max. Wind Speed |
How Many Meters Per Second |
|
Max. thickness of ice coverage |
Winter Max. thickness of ice coverage |
|
Max., Min., Avg. temperature |
-℃~+℃ |