Applications
The EPFU cable can be used as the indoor drop cable in FTTH networks and can be laid by air blowing with a handheld device, to connect the family multimedia information boxes with the access point for subscribers.
- Excellent Air blowing Performance
- FTTx Networks
- Last Mile
- Microduct
Cable Section Design
Features
2, 4, 6, 8 and 12 fibers options Small diameter & Light wight Durable, flexible, soft, easilty stripping design Blowing distance over 1km Temperature range from - 30℃ to +60℃
Standards & Certifications
- [ITU-T G.657.A1] [ISO 9001, 14001]
- [IEC 60793, 60794-5-10, 60794-5-20]
Technical Characteristics
Type |
Fibre count |
O.D. (mm) |
Weight (Kg/km) |
Tensile strengthLong/short term (N) |
Crush resistance short term (N/100mm) |
EPFU-02B6a2 |
2 |
1.1 |
1.1 |
0.15G/0.5G |
100 |
EPFU-04B6a2 |
4 |
1.1 |
1.1 |
0.15G/0.5G |
100 |
EPFU-06B6a2 |
6 |
1.3 |
1.3 |
0.15G/0.5G |
100 |
EPFU-08B6a2 |
8 |
1.5 |
1.8 |
0.15G/0.5G |
100 |
EPFU-12B6a2 |
12 |
1.6 |
2.2 |
0.15G/0.5G |
100 |
Blowing Characteristics
Fibre count |
2 |
4 |
6 |
8 |
12 |
Duct diameter |
5.0/3.5 mm |
5.0/3.5 mm |
5.0/3.5 mm |
5.0/3.5 mm |
5.0/3.5 mm |
Blowing pressure |
8bar / 10bar |
8bar / 10bar |
8bar / 10bar |
8bar / 10bar |
8bar / 10bar |
Blowing distance |
500m/1000 m |
500m/1000 m |
500m/1000 m |
500m/1000 m |
500m/800 m |
Blowing time |
15min/30min |
15min/30min |
15min/30min |
15min/30min |
15min/30min |
Environmental Characteristics
• Transport/storage temperature: -40℃ to +70℃
Delivery Length
• Standard length: 2,000m; other lengths are also available
Mechanical and Environmental Test.
Item
|
Details
|
Tensile loading test
|
Test Method: Accordance with IEC60794-1-21-E1 Tensile force : W*G N Length: 50m Holding time : 1 minutes Diameter of mandrel: 30 x cable diameter After test the fiber and cable no damage and no obvious change in attenuation
|
Crush / Compression test
|
Test Method: Accordance with IEC 60794-1-21-E3 Test Length: 100 mm Load: 100 N Holding time: 1 minutes Test result: Additional attenuation ≤0.1dB at 1550nm. After test no sheath cracking and no fiber breakage.
|
Cable bending test
|
Test Method: Accordance with IEC 60794-1-21-E11B Mandrel Diameter: 65mm Number of Cycle: 3 cycles Test result: Additional attenuation ≤0.1dB at 1550nm. After test no sheath cracking and no fiber breakage.
|
Flexing / Repeated Bending test
|
Test Method: Accordance with IEC 60794-1-21- E8/E6 Mass of the weight : 500g Bending diameter : 20 x diameter of cable Impact rate : ≤ 2 sec / cycle Number of cycles : 20 Test result: Additional attenuation ≤0.1dB at 1550nm. After test no sheath cracking and no fiber breakage.
|
Temperature cycling test
|
Test Method: Accordance with IEC 60794-1-22-F1 Variation of temperature : -20℃ to + 60℃ Number of cycles : 2 Holding time per each step : 12 hours Test result: Additional attenuation ≤0.1dB/km at 1550nm.
|
Cable Marking
Unless otherwise required the sheath will be use inkjet marked at intervals of 1m, containing: - Customer name - Manufacture’s name - Date of manufacture - Type and number of fiber cores - Length marking
- Other requirements
Environmentally
Full comply with ISO14001, RoHS and OHSAS18001.
Cable Packing
Free coiling in the pan. Pans in plywood pallets Standard delivery lengths are 2, 4, 6 km with a tolerance of -1%~+3%.
|
Fibre Count |
Length |
Pan Size |
Weight (Gross) KG |
(m) |
Φ×H |
|
(mm) |
2~4 Fibres |
2000 m |
φ510 × 200 |
8 |
4000 m |
φ510 × 200 |
10 |
6000m |
φ510 × 300 |
13 |
6 Fibres |
2000 m |
φ510 × 200 |
9 |
4000 m |
φ510 × 300 |
12 |
8 Fibres |
2000 m |
φ510 × 200 |
9 |
4000 m |
φ510 × 300 |
14 |
12 Fibres |
1000 m |
φ510 × 200 |
8 |
2000 m |
φ510 × 200 |
10 |
3000m |
φ510 × 300 |
14 |
4000 m |
φ510 × 300 |
15 |