The 2~24 Fibers ASU Cable(AS80 and AS120) is a Self-Supported Optical Cable, It was developed to provide the connection between devices, being indicated for installation in urban and rural networks, in spans of 80m or 120m. Because it is self-supported and totally dielectric, it has FRP strength member as a traction element, thus avoiding electrical discharges in the networks. It is easy to handle and install, eliminating the need to use strings or grounding.
It is mainly used in the communication route of overhead high voltage transmission system, and can also be used in the communication line under the environment such as lightning zone and long distance overhead line.
Structure Design

Main Features:
High strength non-metal strength member
Shorter span: 80m, 100m, 120m
Small size and light weight
Good UV radiation resistance
Life time more than 30 years
Easy operation
ASU Cable VS ASU Cable
Compared with the stranded ADSS fiber optic cable, This fiber optic cable can not only save the use of imported aramid yarn, but also reduce the manufacturing cost due to the reduction of the overall structure size. Compared with the common 150-meter span ADSS-24 fiber optic cable , the price of the This cable of the same specification can be reduced by 20% or more.
Optical Fiber & Cable Technical Pameters:
The Fiber Color Code

Optical Characteristics
Fiber Type |
G.652 |
G.655 |
50/125μm |
62.5/125μm |
Attenuation (+20℃) |
850 nm |
|
|
≤3.0 dB/km |
≤3.3 dB/km |
1300 nm |
|
|
≤1.0 dB/km |
≤1.0 dB/km |
1310 nm |
≤0.36 dB/km |
≤0.40 dB/km |
|
|
1550 nm |
≤0.22 dB/km |
≤0.23 dB/km |
|
|
Bandwidth |
850 nm |
|
|
≥500 MHz-km |
≥200 Mhz-km |
1300 nm |
|
|
≥500 MHz-km |
≥500 Mhz-km |
Numerical Aperture |
|
|
0.200±0.015 NA |
0.275±0.015 NA |
Cable Cut-off Wavelength λcc |
≤1260 nm |
≤1450 nm |
|
|
ASU Cable Technical Pameters:
Fiber Count |
Nominal Diameter (mm) |
Nominal Weight (kg/km) |
Allowable Tensile Load (N) |
Allowable Crush Resistance(N/100mm) |
Short Term |
Long Term |
Short Term |
Long Term |
1~12 |
7 |
48 |
1700 |
700 |
1000 |
300 |
14~24 |
8.8 |
78 |
2000 |
800 |
1000 |
300 |
TEST REQUIREMENTS
Approved by various professional optical and communication product institution, GL also conduct various in-house testing in its own Laboratory and Test Center. She also conduct test with special arrangement with the Chinese Government Ministry of Quality Supervision & Inspection Center of Optical Communication Products (QSICO). GL possess the technology to keep its fiber attenuation loss within Industry Standards.
The cable is in accordance with applicable standard of cable and requirement of customer. The following test items are carried out according to corresponding reference. Routine tests of optical fiber.
Mode field diameter |
IEC 60793-1-45 |
Mode field Core/clad concentricity |
IEC 60793-1-20 |
Cladding diameter |
IEC 60793-1-20 |
Cladding non-circularity |
IEC 60793-1-20 |
Attenuation coefficient |
IEC 60793-1-40 |
Chromatic dispersion |
IEC 60793-1-42 |
Cable cut-off wavelength |
IEC 60793-1-44 |
Tension Loading Test |
|
Test Standard |
IEC 60794-1 |
Sample length |
No less than 50 meters |
Load |
Max. installation load |
Duration time |
1 hour |
Test results |
Additional attenuation:≤0.05dB No damage to outer jacket and inner elements |
Crush/Compression Test |
|
Test Standard |
IEC 60794-1 |
Load |
Crush load |
Plate size |
100mm length |
Duration time |
1 minute |
Test number |
1 |
Test results |
Additional attenuation:≤0.05dB No damage to outer jacket and inner elements |
Impact Resistance Test |
|
Test Standard |
IEC 60794-1 |
Impact energy |
6.5J |
Radius |
12.5mm |
Impact points |
3 |
Impact number |
2 |
Test result |
Additional attenuation:≤0.05dB |
Repeated Bending Test |
|
Test Standard |
IEC 60794-1 |
Bending radius |
20 X diameter of cable |
Cycles |
25 cycles |
Test result |
Additional attenuation: ≤ 0.05dB No damage to outer jacket and inner elements |
Torsion/Twist Test |
|
Test Standard |
IEC 60794-1 |
Sample length |
2m |
Angles |
±180 degree |
cycles |
10 |
Test result |
Additional attenuation:≤0.05dB No damage to outer jacket and inner elements |
Temperature cycling Test |
|
Test Standard |
IIEC 60794-1 |
Temperature step |
+20℃ →-40℃ →+85℃→+20℃ |
Time per each step |
Transition from 0℃ to -40℃:2hours; duration at -40℃:8 hours; Transition from -40℃ to +85 ℃:4hours; duration at +85℃:8 hours; Transition from +85℃ to 0℃:2hours |
Cycles |
5 |
Test result |
Attenuation variation for reference value (the attenuation to be measured before test at +20±3℃) ≤ 0.05 dB/km |
Water penetration Test |
|
Test Standard |
IEC 60794-1 |
Height of water column |
1m |
Sample length |
1m |
Test time |
1 hour |
Test resul |
No water leakage from the opposite of the sample |