Pandan 20 ane ki sot pase yo, câbles nou yo te etabli yon rezo lavant vaste atravè mond lan. Pou kounye a, GL FIBER®te bati repitasyon li kòm yon founisè dirijan nan gwo-entegrite pwodwi kominikasyon optik pa apwovizyone pwodwi ak pi bon kalite a kòm byen ke yo te angaje nan bezwen kliyan nou yo. Tout solisyon Customized yo disponib nan GL FIBER, ki gen ladan apeprè 70% nan pwodwi sou sit entènèt nou an.
CustomFib Optique Câbles
GL Fib®ofri plis pase 2000 kalite câbles fib optik deyò pou aplikasyon pou ayeryen / kanal / dirèk antere l ', epi nou tou sipòte sèvis OEM pou FTTX / Air mouche / Smart Grid Pwojè, Bay vout la vas nan opsyon pou konsepsyon kab fib optik, li kapab yon defi pou jwenn koneksyon w ap chèche yo. Ou ka toujou rele nou ak nenpòt kesyon oswa enkyetid epi pale ak pwofesyonèl konesans nou yo.
Kalite Konvansyonèl yoCâbles fibre optique
Kalite | NON. | Deskripsyon | Kalite fib | Nwayo Fib | Aplikasyon | ||
Ayeryen | Kannal | Antere | |||||
OPGW | OPGW-24B1-80 [71.2;52.1] OPGW-48B1-93 [78.8;53.9] OPGW-48B1-107 [79.9;93.2] OPGW-48B1-150 [96.0;197.0] | Aliminyòm revèti PBT Tib OPGW Kab | G652D G655 | 12/24/36/48/96 | √ | ||
OPGW-12B1-57[69.6;25.3] OPGW-24B1-58 [44.4;24.0] OPGW-24B1-65 [82.7;22.6] OPGW-12B1-75 [77.4;33.5] | SantralTib asye pur OPGW Kab | G652D G655 | 12/24/36/48/96 | √ | |||
OPGW-16B1-80 [69.6;46.6] OPGW-24B1-100 [63.0;75.2] OPGW-24B1-115 [90.1;81.0] OPGW-24B1-163 [109.8;198.3] | Stranded Nerjaveèi Tib Kalite OPGW Kab | G652D G655 | 12/24/36/48/96/144 | √ | |||
OPGW-24B1-70 [70.1;33.9] OPGW-24B1-80 [61.8;52.0] OPGW-16B1-96 [75.3;106.9] OPGW-24B4-110[105;85.8] | Santral AL ki kouvri Nerjaveèi Tib Kalite OPGW Kab | G652D G655 | 12/24/36/48/96 | √ | |||
ADSS-SJ | ADSS-SJ-80 ADSS-SJ-100 ADSS-SJ-120 ADSS-SJ-150 ADSS-SJ-200 | ADSS-SJ-100 Single Jacket ADSS G.652D span 80m ADSS-SJ-100 Single Jacket ADSS G.652D span 100m ADSS-SJ-120 Single Jacket ADSS G.652D span 120m ADSS-SJ-120 Single Jacket ADSS G.652D span 150m ADSS-SJ-200 Single Jacket ADSS G.652D span 200m | G652D G655 | 6/12/24/36/48/96/144 | √ | ||
ADSS-DJ | ADSS-DJ-200 ADSS-DJ-300 ADSS-DJ-400 ADSS-DJ-600 ADSS-DJ-800 ADSS-DJ-1000 | ADSS-DJ-100 doub Jacket ADSS G.652D span 200m ADSS-DJ-100 doub Jacket ADSS G.652D span 300m ADSS-DJ-120 doub Jacket ADSS G.652D span 400m ADSS-DJ-120 doub Jacket ADSS G.652D span 600m ADSS-DJ-200 doub Jacket ADSS G.652D span 800m ADSS-DJ-200 doub Jacket ADSS G.652D span 800m | G652D G655 | 6/12/24/36/48/96/144/288 | √ | ||
ASU kab | ASU-80-100-120 | ASU Single Jacket Mini ADSS G.652D span 80m
ASU Single Jacket Mini ADSS G.652D span 100m
ASU Single Jacket Mini ADSS G.652D span120m
| G652D | 6/12/24 | √ | ||
GJXH | GJXH-1 GJXH-2 GJXH-4 GJXH-6 GJXH-8 GJXH-12 | GJXH-1 G657A (Steel) Drop kab GJXH-2 G657A (Steel) Drop kab GJXH-4 G657A (Steel) Drop kab GJXH-6 G657A (Steel) Drop kab GJXH-8 G657A (Steel) Drop kab GJXH-12 G657A (Steel) Drop kab | G657A1/ G657A2 | 1/2/4/6/8/12 | √ | ||
GJXFH | GJYXCH-1 GJYXCH-2 GJYXCH-4 GJYXCH-6 GJYXCH-8 GJYXCH- 12 | GJXH-1 G657A (FRP) Drop kab GJXH-2 G657A (FRP) Drop kab GJXH-4 G657A (FRP) Drop kab GJXH-6 G657A (FRP) Drop kab GJXH-8 G657A (FRP) Drop kab GJXH-12 G657A (FRP) Drop kab | G657A1/ G657A2 | 1/2/4/6/8/12 | √ | ||
GJYXCH | GJYXCH-1 GJYXCH-2 GJYXCH-4 GJYXCH-6 GJYXCH-8 GJYXCH- 12 | GJYXCH-1 G657A (Asye) Oto-sipòte kab gout GJYXCH-2 G657A (Steel) Oto-sipòte kab gout GJYXCH-4 G657A (Steel) Self-Supporting Drop kab GJYXCH-6 G657A (Steel) Oto-sipòte kab gout GJYXCH-8 G657A (Steel) Oto-sipòte kab gout GJYXCH-12 G657A (Steel) Oto-sipòte kab gout | G657A1/ G657A2 | 1/2/4/6/8/12 | √ | ||
GJYXFCH | GJYXFCH-1 GJYXFCH-2 GJYXFCH-4 GJYXFCH-6 GJYXFCH-8 GJYXFCH-12 | GJYXFCH-1 G657A (Asye) Oto-sipòte GFRP Drop kab GJYXFCH-2 G657A (Asye) Oto-sipòte GFRP Drop kab GJYXFCH-4 G657A (Asye) Oto-sipòte GFRP Drop kab GJYXFCH-6 G657A (Asye) Oto-sipòte GFRP Drop kab GJYXFCH-8 G657A (Asye) Oto-sipòte GFRP Drop kab GJYXFCH-12 G657A (Asye) Oto-sipòte GFRP Drop kab | G657A1/ G657A2 | 1/2/4/6/8/12 | √ | ||
GYTA | GYTA 2-48 GYTA > 48 | Stranded Loose Tube Cable GYTA 2-48 nwayo G.652D Stranded Loose Tube Cable GYTA > 48 cores G.652D | G652D | 2/4/8/12/24/36/48/96/144/288 | √ | ||
GYTS | GYTS 2-48 GYTS > 48 | Stranded tib ki lach kab GYTS 2-48 nwayo G.652D Stranded Loose Tube Cable GYTS > 48 cores G.652D | G652D | 2/4/8/12/24/36/48/96/144/288 | √ | √ | |
GYXTY | GYXTY 2-48 GYXTY > 48 | Stranded tib ki lach kab GYXTY 2-48 nwayo G.652D Stranded Loose Tube Cable GYXTY > 48 cores G.652D | G652D | 2/4/8/12/24/36/48/96 | √ | √ | |
GYFXTY | GYFXTY-4 GYFXTY-6 GYFXTY-8 GYFXTY-12 | Ki pa metalik ki pa blende fib optik kab GYFXTY | G652D | 2/4/8/12/24 | √ | √ | |
GYFXTBY | GYFXTBY-4 GYFXTBY-6 GYFXTBY-8 GYFXTBY-12 | Ki pa metalik ki pa blende plat fibre optique kab GYFXTBY | G652D | 2/4/8/12/24 | |||
GYXTW | GYXTW-4 GYXTW-6 GYXTW-8 GYXTW-12 | Unitube limyè-blende kab GYXTW 4 nwayo G.652D Unitube limyè-blende kab GYXTW 6 nwayo G.652D Unitube limyè-blende kab GYXTW 8 nwayo G.652D Unitube limyè-blende kab GYXTW 12 nwayo G.652D | G652D | 2/4/8/12/24 | √ | √ | |
GYFTY | GYFTY 2-48 GYFTY > 48 | Stranded tib ki lach kab GYFTY 2-48 nwayo G.652D Stranded Loose Tube Cable GYFTY > 48 cores G.652D | G652D | 2/4/8/12/24/36/48/96/144/288 | √ | √ | |
GYFTA(S) | GYFTA(S) 2-48 GYFTA(S > 48 | Stranded Loose Tube Cable GYFTA(S 2-48 cores G.652D Stranded Loose Tube Cable GYFTA(S > 48 cores G.652D | G652D | 2/4/8/12/24/36/48/96/144/288 | √ | √ | |
GYTA33/333 | GYTA53 2-48 GYTA53 > 48 | UG doub gaine kab GYTA53 2-48 cœurs G.652D UG doub gaine kab GYTA53 > 48 cœurs G.652D | G652D | 2/4/8/12/24/36/48/96/144/288 | √ | √ | |
GYTS33/333 | GYTS53 2-48 GYTS53 > 48 | UG doub gaine kab GYTS53 2-48 cœurs G.652D UG doub gaine kab GYTS53 > 48 cœurs G.652D | G652D | 2/4/8/12/24/36/48/96/144/288 | √ | √ | |
GYTA53+33/333 | GYTA53+33/333 2-48 GYTA53+33/333 > 48 | UG doub gaine kab GYTA53+33/333 2-48 nwayo G.652D UG doub gaine kab GYTA53+33/333 > 48 nwayo G.652D | G652D | 2/4/8/12/24/36/48/96/144/288 | √ | √ | |
GYFTA53 | GYFTA53 2-48 GYFTA53 > 48 | Direct Buried(UG) Double Armor Double Jacket GYFTA53 2-48 nwayo G.652D Direct Buried(UG) Double Armor Double Jacket GYFTA53 G.652D > 48 nwayo | G652D | 2/4/8/12/24/36/48/96/144/288 | √ | √ | |
GYTY53 | GYTY53 2-48 GYTY53 > 48 | Direct Buried(UG) Single Armor Double Jacket GYTY53 2-48 nwayo G.652D Direct Buried(UG) Single Armor Double Jacket GYTY53 G.652D > 48 nwayo | G652D | 2/4/8/12/24/36/48/96/144/288 | √ | √ | |
GYFTY53 | GYFTY53 2-48 GYFTY53 > 48 | Direct Buried(UG) Single Armor Double Jacket GYFTY53 2-48 nwayo G.652D Direct Buried(UG) Single Armor Double Jacket GYFTY53 G.652D > 48 nwayo | G652D | 2/4/8/12/24/36/48/96/144/288 | √ | √ | |
GYTC8A(S) | GYTC-8A/S | Figi 8 Kab GYTC-8A G.652D Figi 8 Kab GYTC-8S G.652D | G652D | 2/4/8/12/24/36/48/96/144/288 | √ | ||
GYXTC8A(Y) | GYXTC-8S/Y | Figi 8 Kab GYXTC-8S 2-12 nwayo G.652D Figi 8 Kab GYXTC-8Y 2-12 nwayo G.652D | G652D | 2/4/8/12/24/36/48/96/144/288 | √ | ||
GYFC8Y | GYFC8Y 2-144 | Figi 8 Kab GYFC8Y 2-144 Cores G.652D | G652D | 2/4/8/12/24/36/48/96/144/288 | √ | ||
GYFC8Y53 | GYFC8Y53 2-144 | Figi 8 KabGYFC8Y532-144 Nwayo G.652D | G652D | 2/4/8/12/24/36/48/96/144/288 | √ | √ | |
GCYFY | GCYFY 1-576 | Bloke Tib ki lach Air-kònen Micro Kab | G652D /G657A1/G657A2 | 2/4/8/12/24/36/48/96/144/288 | √ | ||
GCYFXTY | GCYFXTY 1-24 | Uni-tib Air-kònen Micro Kab | G652D /G657A1/G657A2 | 2/4/8/12/24/36/48/96/144/288 | √ | ||
EPFU | EPFU 1-12 | Inite Fib Pèfòmans Amelyore | G652D /G657A1/G657A2 | 2/4/8/12 | √ | ||
SFU | SFU 1-12 | SFU Smooth Fibre Inite | G652D /G657A1/G657A2 | 2/4/8/12 | √ |
Custom OEM Fibre Optique Kab Asanble
Jesyon kab fib (ODN)
Asanble fib optik
Foto | Non pwodwi | Deskripsyon | Mande |
Adaptè | Adaptè fib optik (ke yo rele tou bulkheads) yo itilize yo rantre nan de câbles patch fib optik ansanm. Yo disponib pou itilize swa swa monomode oswa multimode patch câbles. | Mande | |
Vit Connector | Lachin FIBERFUTURE bay plizyè kalite SM ak MM konektè vit pou aplikasyon pou LC, SC, FC, ST. Chak konektè yo teste fonksyonèl anvan anbake. | Mande | |
Splitter | Endikatè fib optik PLC splitter yo baze sou teknoloji waveguide planè a. Splitter PLC fib optik la bay yon solisyon distribisyon pouvwa a pri ki ba ak pafè ki gen karakteristik ti faktè fòm ak segondè fyab. Wide fonksyònman ranje longèdonn ak bon inifòmite chanèl-a-chanèl fè Splitter fib PLC lajman ki itilize nan nèt PON. | Mande | |
Patch kòd | FTTH fib patch kòd oswa pigtail, refere a kab gout la fini ak yon ploge konektè, yo itilize pou reyalize koneksyon optik aktif, tou dwe fèt nan yon pigtails tèt sèl, ak Splice fleksib, Quick konekte ak lòt pwodwi konbine aplikasyon, kalite Connector yo se SC -PC(APC) ak FC-PC(APC). | Mande | |
Pigtails | Fib optik pigtail se yon kab fib optik ki kouvri nan chak fen ak konektè ki pèmèt kab fib optik pigtail yo dwe rapidman ak fasilman konekte ak CATV, yon switch optik oswa lòt ekipman telekominikasyon. Kouch epè pwoteksyon asanble pigtail fib la itilize pou konekte transmetè optik, reseptè a ak bwat tèminal la. | Mande |
GL FIBER ofri pi gwo seleksyon nan câbles patch fib. Si seleksyon an nan estoke fib patch câbles pa satisfè bezwen ou yo, nou ka ofri sèvis koutim ba ou. Tanpri itilize fòm ki anba a pou konstwi ak kòmande câbles koutim ou ak lavant nou yo. Si w jwenn bezwen ou yo pa satisfè pa opsyon ki nan fòm ki anba a, tanpri voye detay nan lavant nou yo epi nou pral desine câbles espesyalite pou satisfè bezwen ou yo.