What is the ADSS fiber optic cable?
As we all know that All-Dielectric Self-Supporting ADSS Optical Cable is idea for installation in distribution as well as transmission envirline installations are required as its name indicates, there is no support or messenger wire required, so installation is achieved in a single pass.Structural features:Double layer、Single layer ,Loose tube stranding, Non-metal strength member, Half dry water-blocking, Aramid yarn strength member, PE outer jacket. Includes 2 core, 4 core, 6 core, 8 core, 12 core, 16 core, up to 288 cores.
Today, let us have a discussion on the topic of what is the different between single jacket ADSS Cable and Double Jacket ADSS Cable?
All Dielectric Self-Supporting cable (Single Jacket)
Construction:
- 1. Optical Fiber
- 2. Inner Jelly
- 3. Loose Tube
- 4. Filler
- 5. Central Strength Member
- 6. Water Blocking Yarn
- 7. Water Blocking Tape
- 8. Rip Cord
- 9. Strength Member
- 10. Outer Sheath
Features:
- 1. Standard fiber count: 2~144 core ·
- 2. Protection from lightning and electrical interference ·
- 3. UV-resistant outer jacket & Water blocked cable ·
- 4. High tensile strength & long term reliability ·
- 5. Stable and highly reliable transmission parameters
Applications: Low-voltage transmission and distribution system · Railways and Telecommunications pole route · Suitable for all type of aerial lines
Specifications:
Fiber Count | No. of Tube | No. of Fibers per Tube | Outer Diameter (mm) | Weight (km/kg) |
2~12 | 1 | 1~12 | 11.3 | 96 |
24 | 2 | 12 | ||
36 | 3 | 12 | ||
48 | 4 | 12 | 12.0 | 105 |
72 | 6 | 12 | ||
96 | 8 | 12 | 15.6 | 180 |
144 | 12 | 12 | 17.2 | 215 |
Characteristics:
Characteristics | Specifications | |
SPAN | 100m | |
Max. Tensile Load | 2700N | |
Crush Resistance | Short Term | 220N/cm |
Long Term | 110N/cm | |
Bending Radius | Installation | 20 times of cable OD |
Operation | 10 times of cable OD | |
Temperature Range | Installation | -30℃ ~ + 60℃ |
Operation | -40℃ ~ + 70℃ |
All Dielectric Self-Supporting cable (Double Jacket)
Construction:
- 1. Optical Fiber
- 2. Inner Jelly
- 3. Loose Tube
- 4. Filler
- 5. Central Strength Member
- 6. Water Blocking Yarn
- 7. Water Blocking Tape
- 8. Rip cord
- 9. Strength Memebr
- 10. Inner Sheath
- 11. Outer Sheath
Features:
- 1. Standard fiber count: 2~288 core
- 2. Protection from lightning and electrical interference
- 3. UV-resistant outer jacket & Water blocked cable
- 4. High tensile strength & long term reliability
- 5. Stable and highly reliable transmission parameters
Applications: Low-voltage transmission and distribution system · Railways and Telecommunications pole route · Suitable for all type of aerial lines
Specifications:
Fiber Count | No. of Tube | No. of Fibers per Tube | Outer Diameter (mm) | Weight (km/kg) |
6 | 1 | 1~12 | 12.8 | 125 |
12 | 1 | 12 | ||
24 | 2 | 12 | ||
36 | 3 | 12 | ||
48 | 4 | 12 | 13.3 | 135 |
72 | 6 | 12 | ||
96 | 8 | 12 | 14.6 | 160 |
144 | 12 | 12 | 17.5 | 230 |
216 | 18 | 12 | 18.4 | 245 |
288 | 24 | 12 | 20.4 | 300 |
Characteristics:
Characteristics | Specifications | |
SPAN | 200m~400m | |
Max. Tensile Load | 2700N | |
Crush Resistance | Short Term | 220N/cm |
Long Term | 110N/cm | |
Bending Radius | Installation | 20 times of cable OD |
Operation | 10 times of cable OD | |
Temperature Range | Installation | -30℃ ~ + 60℃ |
Operation | -40℃ ~ + 70℃ |
All the above is the basci Charactristics and applications of ADSS fiber optic cables, if you are interested on ADSS, you can call us or email for more.